-EX
Owner’s Manual
V480360 R0 1 IP 16
E
200 AP Printed in Japan
■ Precautions
• Do not allow water to enter this unit or allow the unit
to become wet. Fire or electrical shock may result.
• The digital circuits of this unit may induce a slight
noise into nearby radios and TVs. If noise occurs,
relocate the affected equipment.
• Connect this unit’s power cord only to an AC outlet of
the type stated in this Owner’s Manual or as marked
on the unit. Failure to do so is a fire and electrical
shock hazard.
• If the message “WARNING LOW BATTERY!” appears
when you turn on this unit, contact your dealer as
soon as possible about replacing the internal data
backup battery. The unit will still operate correctly,
but data other than the presets will be lost.
Before you replace the battery, store your data to an
ATA-compliant PC flash storage card via the CS1D, or
store the data to the personal computer by connecting
the computer to the PC CONTROL “RS-232-C” con-
nector on the DSP1D/DSP1D-EX.
• Do not scratch, bend, twist, pull, or heat the power
cord. A damaged power cord is a fire and electrical
shock hazard.
• Do not place heavy objects, including this unit, on top
of the power cord. A damaged power cord is a fire and
electrical shock hazard. In particular, be careful not to
place heavy objects on a power cord covered by a car-
pet.
• The unit is equipped with the ground connector to
avoid the risk of electrical shock.
Be sure to ground the unit before you insert the power
plug into an AC outlet.
• Be sure to ground the unit to avoid the risk of electri-
cal shock
• If you notice any abnormality, such as smoke, odor, or
noise, or if a foreign object or liquid gets inside the
unit, turn it off immediately. Remove the power cord
from the AC outlet. Consult your dealer for repair.
Using the unit in this condition is a fire and electrical
shock hazard.
If the power cord has three pins and the ground con-
nector on the AC outlet is grounded, the unit will be
grounded effectively.
• Should this unit/AC adapter/power supply be
dropped or the cabinet be damaged, turn the power
switch off, remove the power plug from the AC outlet,
and contact your dealer. If you continue using the unit
without heeding this instruction, fire or electrical
shock may result.
• If the power cord is damaged (i.e., cut or a bare wire is
exposed), ask your dealer for a replacement. Using the
unit with a damaged power cord is a fire and electrical
shock hazard.
• Do not remove the unit’s cover. You could receive an
electrical shock. If you think internal inspection,
maintenance, or repair is necessary, contact your
dealer.
• Do not modify the unit. Doing so is a fire and electri-
cal shock hazard.
• When rack-mounting the unit, allow enough free
space around the unit for normal ventilation. This
should be: 10 cm behind, and 20 cm above.
• For normal ventilation during use, remove the rear of
the rack or open a ventilation hole.
• If the airflow is not adequate, the unit will heat up
inside and may cause a fire.
• This unit has ventilation holes at the rear and bottom
to prevent the internal temperature rising too high.
Do not block them. Blocked ventilation holes are a fire
hazard.
• Hold the power cord plug when disconnecting it from
an AC outlet. Never pull the cord. A damaged power
cord is a potential fire and electrical shock hazard.
• Do not touch the power plug with wet hands. Doing
so is a potential electrical shock hazard.
3
Thank you for choosing the DSP unit “DSP1D/DSP1D-EX”, specifically designed for the Yamaha PM1D
digital audio mixing system. The DSP1D/DSP1D-EX is an engine controlled by the CS1D control surface.
Be sure to ask an authorizedYamaha service engineer to install the boards and
set up the unit. Never perform installation and setup by yourself.
The following optional boards can be installed in the DSP1D.
• CIB1D : Console interface board
• EMB1D : Engine management board
• PDB1D : Patch DSP board
• GDB1D : Group DSP board
• EDB1D : Effect DSP board
• IDB1D : Input DSP board
■ Front panel
ENGINE ID
1
A
B
CONTROL I/O
2
3
ENGINE ID
1
2
A
B
CONTROL I/O
1
2
INPUT
CONFIGURATION
INPUT
CONFIGURATION
48CH
96CH
POWER
ON/ OFF
48CH
96CH
POWER
ON/ OFF
4
■ Rear panel
MIDI
CONTROL I/O
CONSOLE
L M N
O
1
IN
DIGITAL I/O
IN
OUT
THRU
CONSOLE
I/O
CASCADE
OUTPUT
INPUT
OUT
5
6
7
8
1
IN
5
3
1
9
7
5
3
1
2
IN
OUT
MIDI
CONTROL I/O
CONSOLE
DIGITAL I/O
CONSOLE
I/O
CASCADE
OUTPUT
INPUT
1
IN
PC
CONTROL
1
IN
5
3
1
9
7
3
1
IN
OUT
THRU
OUT
2
REMOTE
RS-422
IN
OUT
PC
CONTROL
REMOTE
RS-422
RS-232-C
RS-232-C
9
J
K
2
OUT
6
4
2
10
8
6
4
2
USB
GPI
WORD CLOCK
IN
OFF
75Ω
ON
TIME CODE IN
OUT
USB
GPI
2
OUT
6
4
2
10
8
6
4
2
WORD CLOCK
IN
OFF
75Ω
ON
TIME CODE IN
OUT
P
4
AENGINE ID A/B indicators
DPOWER ON/OFF switch
These indicators indicate whether the DSP1D/
DSP1D-EX is connected to the engine A or engine B
channel.
Use this switch to turn the power to the DSP1D/
DSP1D-EX on or off. When the power is turned on,
the indicators 1- 3light up.
Indicator A lights up if the DSP1D/DSP1D-EX is con-
nected to the engine A channel jacks of the CS1D con-
trol surface (DIGITAL I/O jack A and CONTROL I/O
jack A). Indicator B lights up if the DSP1D/DSP1D-
EX is connected to the engine B channel jacks of the
CS1D control surface (DIGITAL I/O jack B and CON-
TROL I/O jack B).
EMIDI IN/OUT/THRU connectors
These connectors are used to transmit and receive
Program change messages, MMC, and other MIDI
messages among external MIDI devices.
FPC CONTROL RS-232-C/USB ports
Connect these ports to a PC that runs Windows 95 or
Windows 98 to control the PM1D system from the
PC. Use a D-sub, 9-pin cross cable (female to female)
to connect the RS-232-C port to the serial (COM)
port on the PC. The USB port is provided for future
system expansion, but it is not operative in the current
software version.
Error indication
• If both ENGINE ID A and B indicators are flash-
ing:
→
There is a malfunction in the internal board
(PDB, GDB, IDB1/2, EDB, EMB, or CIB). Or
the necessary board does not exist.
GWORD CLOCK IN jack, 75 Ω ON/OFF
switch, and WORD CLOCK OUT jack
The WORD CLOCK IN jack is used to provide word
clock to the PM1D system from the connected exter-
nal device, such as a clock generator. Use the WORD
CLOCK OUT jack to provide the word clock to the
connected external device from the PM1D. Use a BNC
cable with an impedance of 75 Ω for the WORD
CLOCK IN/OUT jacks.
• If either ENGINE ID A or B indicator is flashing:
→
During the Mirror mode operation, the
ENGINE ID indicator for the unused DSP1D/
DSP1D-EX flashes, indicating that the unit is in
standby mode.
→
If Indicator A is flashing, unit A is in standby
mode. If Indicator B is flashing, unit B is in
standby mode.
The WORD CLOCK ON/OFF switch is used to termi-
nate the word clock connection. Basically, if the
DSP1D/DSP1D-EX is the last device of the word clock
chain, or if nothing is connected to the WORD
CLOCK IN/OUT jacks, set this switch to ON.
BCONTROL I/O 1/2 indicators
These indicators indicate which one of two CON-
SOLE 1, 2 IN/OUT jacks (8) on the rear panel is cur-
rently effective.
Note:
HCONSOLE 1, 2 IN/OUT jacks
These jacks are connected to the CONTROL I/O
CONSOLE jacks of the CS1D control surface to trans-
mit or receive control signals. For connection, use a
genuine Yamaha cable or a BNC cable with an imped-
ance of 50 Ω.
When you turn on the power to the DSP1D/
DSP1D-EX and the CS1D, and communication
between the DSP1D/DSP1D-EX and the CS1D is
established, one of these two indicators lights up. If
neither one lights up, check the connection of the
CONSOLE 1, 2 IN OUT jacks on the rear panel.
IREMOTE RS-422 connector
This D-sub 9-pin connector is used to control a con-
nected tape recorder or a hard disk recorder. Serial
commands can be transmitted through this connector
to play or stop such a recorder.
Error indication
• If the CONTROL I/O 1 indicator is flashing:
→
Communication between the CS1D control
surface and the DSP1D is not established.The
CONSOLE 1, 2 IN OUT jacks or the PC CON-
TROL port is not connected correctly.
This connector is provided for future system expan-
sion, but it is not operative in the current software
version.
CINPUT CONFIGURATION 48CH/96CH
indicators
JGPI connector
This connector is used to connect an external device
that supports GPI (General Purpose Interface), such
as a video editor to control the external device from
the PM1D system or to perform certain functions of
the PM1D system while controlling from the external
device. You can connect a custom-made external
switch here.
This connector is provided for future system expan-
sion, but it is not operative in the current software
version.
These indicators indicate how many input channels
are currently available. On the DSP1D, the 48CH
indicator lights up. On the DSP1D-EX, the 96CH
indicator lights up.
Error indication
• If the INPUT CONFIGURATION 48CH is flashing:
→
The signal is not locking to the word clock.
5
KTIME CODE IN connector
This balanced XLR3-31 connector receives SMPTE
time code (LTC) for analog input from the external
device. The rated input level is –10 dB, and the pin
assignment is as follows.
NOUTPUT 1–6 slot
Use these slots to connect the INPUT connectors of an
analog output unit AO8 series or DIO8 digital I/O
unit to output multi-channel digital audio signals
from the DSP1D/DSP1D-EX. Use a genuine Yamaha
half-pitch 68-pin cable for connection.
1=ground, 2=hot, 3=cold
LCONSOLE I/O 1, 2 slots
OINPUT 1–10 slot
Connect these slots to the DIGITAL I/O CONSOLE
jacks of the CS1D control surface to transmit multi-
channel digital audio signals. Use a genuine Yamaha
half-pitch 68-pin cable for connection.
Use these slots to connect the OUTPUT connectors of
an analog input unit AI8 series or DIO8 digital I/O
unit series to input multi-channel digital audio signals
to the DSP1D/DSP1D-EX. Use a genuine Yamaha
half-pitch 68-pin cable for connection.
MCASCADE IN, OUT slots
PGround connector
Use one of these connectors to cascade two DSP1D/
DSP1D-EX units to transmit multi-channel digital
audio signals. Use a genuine Yamaha half-pitch 68-pin
cable to connect the CASCADE IN (or OUT) to the
CASCADE OUT (or IN) of another DSP1D/DSP1D-
EX.
These connectors are provided for future system
expansion, but they are not operative in the current
software version.
Be sure to ground the unit to avoid the risk of electrical
shock before you insert the power plug into an AC outlet.
This product comes with a 3-pin power cord. If the
ground connector of the AC outlet has already been
grounded, the unit will be grounded effectively by
using the 3-pin power cord.
Grounding the unit is also effective for preventing
hum and other noise.
■ Specifications
<External sync> 39.69 kHz – 50.88 kHz
<Internal sync> 44.1 kHz, 48 kHz
Sampling frequency
USA and Canada : 120 V, 60 Hz
Others : 230 V, 50 Hz
170 W
Power supply
Power consumption
Dimensions (W × H × D)
Weight
480 mm × 408.7 mm × 460.8 mm
33 kg
Operating temperature
Fan circuit
10 – 35˚C
always fixed
Accessories
power cable 2.5 m × 1
Digital I/Os
I/O connectors
DIGITAL I/O INPUT 1 –10
Level
RS-422
Type
D-sub, half-pitch, 68-pin connector (female) × 10
D-sub, half-pitch, 68-pin connector (female) × 6
D-sub, half-pitch, 68-pin connector (female) × 2
D-sub, half-pitch, 68-pin connector (female) × 2
BNC connector × 2
DIGITAL I/O OUTPUT 1 – 6
DIGITAL I/O CASCADE IN, OUT
DIGITAL I/O CONSOLE I/O 1, 2
RS-422
RS-422
RS-422
CONTROL I/O CONSOLE 1 IN, OUT –0.225V — –1.825V/50 Ω
CONTROL I/O CONSOLE 2 IN, OUT –0.225V — –1.825V/50 Ω
BNC connector × 2
REMOTE RS-422
RS-422
D-sub, 9-pin connector (female)
C-MOS IN, Open collector OUT
1 pin: 150mA, 8pin total: 500mA
GPI
D-sub, 25-pin connector (female)
TIME CODE IN
SMPTE format, Nominal –10 dB/10 kΩ XLR-3-31 type connector
MIDI IN, OUT, THRU
PC CONTROL RS-232-C
PC CONTROL USB
WORD CLOCK IN
WORD CLOCK OUT
MIDI format
RS-232-C
5-pin DIN connector × 3
D-sub, 9-pin connector (male)
B type USB connector
BNC connector
0V — 3.3V
TTL/75 Ω (ON/OFF)
TTL/75 Ω
BNC connector
6
Slots (for IDB1D board)
Unit
DPS1D
Input channel
*
INPUT 1-48 & ST IN 1-4
DPS1D-EX
INPUT 1-96 & ST IN 1-8 (DSP1D + IDB1D for expansion)
*The DSP1D has an empty slot available for the IDB1D board.
■ Dimensions
480
ENGINE ID
A
B
CONTROL I/O
1
2
INPUT
CONFIGURATION
48CH
96CH
POWER
ON/ OFF
unit: mm
• Specifications and appearance are subject to change without notice for improvement.
• For European Model
Purchaser/User information specified in EN55103-1 and EN55103-2.
Inrush Current: 31A
Conformed Environment: E1, E2, E3 and E4.
7
YAMAHA CORPORATION
Pro Audio Division, #18/3