NetBlaster ZX410 Series User’s Guide
Fast Ethernet Adapters for CompactPCI Systems
Welcome!
Thank you for choosing the ZNYX NetBlaster CompactPCI Fast Ethernet Adapter. Your
adapter is designed to provide a lifetime of superior service in your CompactPCI system.
CompactPCI is the newest specification for PCI-based industrial and/or embedded computers.
It is electronically compatible with desktop PCI in a different physical form factor.
NetBlaster CompactPCI Fast Ethernet Adapter Models
•
NetBlaster CompactPCI ZX412 provides two 10/100 ports, each with separate IEEE Auto
Negotiation. It is available for 3U and 6U slots.
•
NetBlaster CompactPCI ZX414 provides four 10/100 ports, each with separate IEEE Auto
Negotiation. It is available for 3U and 6U slots.
What’s In the Package
Your purchase of a NetBlaster CompactPCI adapter includes the following items. Please contact
ZNYX Customer Support at (800) 724-0911 if anything is missing from this package.
1. NetBlaster CompactPCI Fast Ethernet adapter (either ZX412 or ZX414).
2. DOS diagnostic and documentation diskette, containing:
•
•
ZNYX NetBlaster CompactPCI User’s Guide (DU011901.PDF)
DOS Diagnostic Program (ZX414.EXE and ZX412.EXE)
Installation Procedure
There are two basic steps you need to follow to operate the NetBlaster CompactPCI adapter.
1. Install the hardware.
2. Install the driver.
To get the most recent operating system specific driver, go to the ZNYX web site at
Technical Support at (800) 724-0911 or [email protected].
ZNYX NetBlaster ZX410 Series User’s Guide
Page 3
Hardware Installation
Below are the steps necessary to install a NetBlaster CompactPCI adapter into a standard,
compliant system. In most systems, the configuration is “plug and play”, which requires no
operations on the part of the installer. The following are detailed instructions for the hardware
installation procedure.
Installing the Hardware
This installation procedure is for installing an adapter into standard, compliant systems. Some
steps in this procedure may vary depending on the specific system used. Refer to the system’s
documentation if necessary.
The figure on the following page shows the installation of an adapter in a typical system.
1. Turn off your system.
2. Discharge any static electricity from your body by touching the metal case, or by using an
anti-static wrist strap. If you do not have a ground strap, maintain physical contact with the
case to maintain the same electrical potential with the system.
3. Select an available CompactPCI slot.
4. Remove the slot cover from the front panel slot filler bracket.
5. Insert the ZNYX adapter into the slot. Make certain that you push the adapter straight
into the slot; the bracket and the slot must be properly aligned and the adapter fully
“seated”. A good “seat” is when the bracket touches the system case, up to the extraction
levers.
6. Pull up on the extraction levers to finish seating the adapter.
7. Secure the retaining screws.
LAN Cable Connection
The LAN cable must be properly attached to a functioning network for the adapter to operate.
100 Mbps connections require Category 5 cabling.
Page 4
ZNYX NetBlaster ZX410 Series User’s Guide
Connecting to the Network
There are two ways to connect the system using twisted pair: (1) system to system; (2) direct
system to hub or switch.
•
You can connect your adapter directly to another system with a null cable. A null cable, or
crossover cable, “crosses over” the transmit and receive pairs. If a null cable cannot be
purchased, the following wiring diagram may be used.
•
You can connect your adapter directly to a hub or switch with an unshielded twisted-
pair (UTP) cable. Make certain that the cable length is within the minimum and
maximum length restrictions for Ethernet, or you could experience signal or data loss.
Driver Installation
This section covers driver installation for the NetBlaster CompactPCI adapter. At this stage the
adapter should be secure in the system and all Ethernet cables should be attached. If this is not
the case, return to the “Hardware Installation” procedure in the previous section.
with the driver is a release note with installation and configuration instructions. Please follow
these directions to configure the driver.
Running DOS Diagnostics
In the following section the notation DIAG41x should be replaced with the appropriate instance
(DIAG412, DIAG414, etc.). In each case, the text will assume that the DOS system has been
started and the EXE program is in the current directory or search path. See your DOS reference
manual for details, if necessary.
Note: Microsoft EMM386 prior to V4.49 is not compatible with PCI systems. The correct version is the copy that
was shipped with the US edition of DOS 6.22. Make sure that you have replaced any version of
EMM386 dated before 31-May-94, even if you are running from a floppy disk drive.
ZNYX NetBlaster ZX410 Series User’s Guide
Page 5
Testing ZX412 and ZX414 Adapters
1. Run the diagnostic program that came with your adapter to see if your adapter has been
properly configured. Run DIAG41x.EXE off your diskette by entering:
>DIAG41x LIST
2. You will see a list below. (This example is for the ZX414.)
DIAG414 Version 1.38 for ZNYX NetBlaster ZX414 4/100 Mbps adapter
(c) Copyright 1994-1998 ZNYX Corporation - All Rights Reserved.
PCI BIOS Information: Version=2.10, Config Mechanism=1, Last Bus=2
Bus Dev Fn Vendor Device Rev Type
Lat IL IRQ Note
========== ================= ============ ========== =====
0 0 0 8086 1250 03 Host Bridge 20 - -
0 7 0 8086 7000 01 PCI-ISA
0 7 1 8086 7010 00 IDE
1 4 0 1011 0019 30 Ethernet
1 5 0 1011 0019 30 Ethernet
1 6 0 1011 0019 30 Ethernet
1 7 0 1011 0019 30 Ethernet
00 - -
20 - -
40 A 9
40 A 3
40 A 10 ZX414
40 A 5 ZX414
ZX414
ZX414
3. If you see a list of two or four 02-Network/00-Ethernet channels, each with an IRQ
(interrupt line), bus value, and a unique device number, your card has been automatically
configured. Make a note of the bus and device numbers and go on to the software installation
section.
4. Test all channels of your adapter by running DIAG41X for each bus number and device
number. For example, if you have a ZX414 the bus number is 1 and the device numbers are
from 4-7, run:
>DIAG414 1 4
>DIAG414 1 5
>DIAG414 1 6
>DIAG414 1 7
5. Substitute the appropriate version of DIAG41X for the adapter used. If the DIAG41X
program says:
Diagnostics successfully completed.
each time, proceed with the software installation.
6. If the DIAG41X program does not indicate a successful completion, refer to the chapter on
troubleshooting in this manual.
Page 6
ZNYX NetBlaster ZX410 Series User’s Guide
Troubleshooting
All NetBlaster CompactPCI adapters support plug-and-play. If you have a plug-and-play system,
your card will configure itself automatically.
If the operating system does not discover the board, try running the diagnostics program (see
previous section).
System-specific Configuration Requirements
As noted earlier, CompactPCI is a plug-and-play bus. This means the host computer program
should automatically assign all system resources, such as I/O addresses and interrupt lines (IRQ).
Occasionally, you may need to assign these resources manually. This is often the case with host
systems and motherboards that are not fully compliant with plug-and-play standards. This is
usually done by modifying your system’s CMOS SETUP program, typically under the section
specifying PCI bus/slot configuration options.
Note: All PCI adapters require level triggered interrupts. NetBlaster CompactPCI adapters will not function
properly using edge triggered interrupts.
Basic Troubleshooting
For all operating systems, we recommend that you try the following if you are having difficulty.
In addition, we have OS-specific troubleshooting suggestions below.
1. Make sure the board is securely seated in the slot.
2. Check the green link LED’s. The LED will be on when attached to an active interface (hub,
switch, router, or any other system). See figure below:
3. Refer to operating system specific documentation to evaluate any error messages or logs
when the driver is loaded.
ZNYX NetBlaster ZX410 Series User’s Guide
Page 7
Technical Support
If you need further assistance after referring to this User’s Guide, ZNYX has a professional
technical support team available to answer your questions. Contact us at:
Tel:
Fax:
(510) 249-0800 or (800) 724-0911
(510) 646-2460
Email: [email protected]
FTP: ftp.znyx.com
You can reach us during normal business hours, Pacific Standard Time.
Appendix A: Legal Notices and Certification
This section contains warranty and other product information notices, which may be required by
local laws.
Warranty
ZNYX Corporation warrants to the original purchaser of any ZNYX NetBlaster CompactPCI
Fast Ethernet adapter product that is to be free from defects in workmanship and materials,
under normal use and service, for the lifetime of the personal computer in which it is installed
from the date of purchase from ZNYX or its authorized dealer. In order for this warranty to be
valid, this hardware product must remain in its original personal computer and be registered with
ZNYX within one year of purchase. Otherwise, ZNYX warrants to the original purchaser of this
hardware product that it is to be in good working order for a period of thirty-six (36) months
from the date of purchase from ZNYX or an authorized dealer.
Should this product, in ZNYX’s opinion, malfunction during the applicable warranty period,
ZNYX will, at its expense, repair the defective product or part or, at its option, deliver to the
Customer an equivalent product or part to replace the defective item. To prevent damage in
transport, the Customer must return the product in its original packaging or, if this is not
available, other protective packaging approved in advance by ZNYX. All returned products will
become the property of ZNYX. At ZNYX’s option, replacement parts may be new or
reconditioned. Any replaced product or part has a ninety (90) day warranty or the remainder of
the initial warranty period, whichever is longer.
This limited lifetime warranty applies to the following ZNYX products only ZX412 and ZX414.
ZNYX warrants all other product(s) for a period of thirty-six (36) months from the date of
purchase from ZNYX, under the same limited warranty terms and conditions.
Certification
Page 8
ZNYX NetBlaster ZX410 Series User’s Guide
Appendix B: Legal Notices and Certification
FCC Class B Notice: NETBLASTER ZX412 AND ZX414
Modification to this product not authorized by ZNYX Corporation could void the FCC
approval and negate your authority to operate the product.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if it is not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However these is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Canada Compliance: NETBLASTER ZX412 AND ZX414
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numeriqué de la classe B est conforme à la norme NMB-003 du Canada.
CE Conformity: NETBLASTER ZX412 AND ZX414
The NetBlaster ZX412 and ZX414 are in compliance to CE testing according to the following
standards with respect to the stated level and given criteria:
EN 55022
EN 50082-1
EN 55022(1994)
Class B
EN 61000-4-2 (1995)
EN 61000-4-3 (1996)/ENV 50204 (1995) 3V/m
EN 61000-4-4 (1995)
EN 61000-4-5 (1995)
EN 61000-4-6 (1996)
EN 61000-4-11 (1994)
4kV (Contact Discharge) and 8kV (Air Discharge)
1kV (Power Supply) and 0.5 kV (I/O Cables)
1kV (Line to Line) and 2kV (Line to Ground)
3Vrms
0%, 40%, 70% of UT, voltage dips +/-10% voltage variations
THIS ADAPTER CARD IS FOR USE ONLY WITH COMPACTPCI BUS COMPATIBLE
SYSTEMS THAT HAVE ENCLOSED POWER SUPPLIES WITH SELV OUTPUTS AND
INSTALLATION INSTRUCTIONS DETAILING USER INSTALLATION OF CARD
CAGE ACCESSORIES.
Manufacturer Name: ZNYX Corporation
Manufacturer Address: 48501 Warm Springs Boulevard, Suite 107, Fremont, CA 94539
ZNYX NetBlaster ZX410 Series User’s Guide
Page 9
Warranty
ZNYX Corporation warrants to the original purchaser of any ZNYX NetBlaster CompactPCI
Fast Ethernet adapter product that is to be free from defects in workmanship and materials,
under normal use and service, for the lifetime of the personal computer in which it is installed
from the date of purchase from ZNYX or its authorized dealer. In order for this warranty to be
valid, this hardware product must remain in its original personal computer and be registered with
ZNYX within one year of purchase. Otherwise, ZNYX warrants to the original purchaser of this
hardware product that it is to be in good working order for a period of thirty-six (36) months
from the date of purchase from ZNYX or an authorized dealer.
Should this product, in ZNYX’s opinion, malfunction during the applicable warranty period,
ZNYX will, at its expense, repair the defective product or part or, at its option, deliver to the
Customer an equivalent product or part to replace the defective item. To prevent damage in
transport, the Customer must return the product in its original packaging or, if this is not
available, other protective packaging approved in advance by ZNYX. All returned products will
become the property of ZNYX. At ZNYX’s option, replacement parts may be new or
reconditioned. Any replaced product or part has a ninety (90) day warranty or the remainder of
the initial warranty period, whichever is longer.
This limited lifetime warranty applies to the following ZNYX products only ZX412 and ZX414.
ZNYX warrants all other product(s) for a period of thirty-six (36) months from the date of
purchase from ZNYX, under the same limited warranty terms and conditions.
Certification
Page 10
ZNYX NetBlaster ZX410 Series User’s Guide
Warranty Registration Card
NetBlaster ™ CompactPCI ®Fast Ethernet Adapter
Please complete and return to ZNYX Corporation:
By Mail
By Fax
ZNYX Corporation
Attn: Warranty Registration
(510) 656-2460
48501 Warm Springs Blvd. Suite 107
Fremont, CA 94539 USA
ZNYX Model Number
Date of Purchase
Serial Number(s)
Where did you purchase your ZNYX product?
How did you
learn about
ZNYX products?
Magazine
Ad
News
Article
Trade
Show
Direct
Mail
Web
Surfing
Word of
Mouth
Other
(specify)
You are a :
First Name
Distributor
Reseller
End User
VAR
Consultant
Other (specify)
Last Name
Title
Division
Company Name
Company Address
Additional Address
City
State
Country
Postal Code/Zip Code
Telephone Number (include area code)
Email Address
Fax Number
URL
Please complete the following system configuration information.
System Manufacturer
Motherboard Manufacturer
BIOS Version
BIOS Manufacturer
Other boards in the system
Ethernet type:
10BaseT
100BaseTX
Please indicate which software is in use with this product (check all that apply)
DOS
Solaris
VxWorks
pSOS
Windows NT
SCO Unix
LynxOS
QNX
Other (specify)
Please indicate your processor:
Intel
PowerPC
SPARC
yes
Alpha
Mips
StrongARM
Other
Would you like additional information on ZNYX products?
no
ZNYX NetBlaster ZX410 Series User’s Guide
Page 11
|